Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine

Product Details
Customization: Available
After-sales Service: Online After Sale Service
Automatic Grade: Semi-Automatic
Still deciding? Get samples of US$ 4300/Piece
Request Sample
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
73901.09 USD
Management System Certification
ISO 9001
  • Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
  • Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
  • Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
  • Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
WS-FM-06-A
Warranty
1 Year
Theory
Reciprocating Pump
Product Name
CO2 Fire Extinguisher Refilling Machine
Pump Type
Horizontal Installed
Drive Air Range
Compressed Air of 3-10 Bar
Drive Power
Compressed Air From Air Compressor
Driven Piston Diameter
160mm
Pump Ratio
6:1 Inside
Working Medium
FM200 and CO2
Usage
Air Pump
Maximum Output Pressure
40 Bar Base on 8 Bar Air Driven Pressure
Transport Package
Wooden Box Packing
Specification
108× 82× 130CM
Trademark
USUN
Origin
Made in Dong Guan / China
HS Code
8463900090
Production Capacity
10 PCS Per Month

Product Description

WHY CHOOSE OUR PUMP SYSTEM?
This brochure introduces pneumatic driven gas/Hydraulic boosters and Complete booster system.

These gas booster pump offer a flexible and efficient source for delivering high pressure gases.

1.Oxygen or High Purity cleaning: Our booster are noted for their cleaniness and can handle pure gases such as

oxygen without risk of any contamination.We will use customized lubricants for oxygen and also clean it with ultrosonice cleaner

2. High Flow rates at High pressure: When High flow rates at high pressure are needed ,the booster
can charge a receiver to an even higher pressure level ,thus storing a volume of gas aviable for rapid release at a constant
pressure through a pressure reducing valve

 
3.Cost savings:Most Industrial gases are commonly delivered at pressure of 2000-2600 Psi in steel cylinders .If the

Gas is to be used well bellow the supply pressure ,the pressurized supply is easily piped  and controlled to the point of use

with simple valving .However,if the end user requires  the gas to be used at higher pressure then the supply it will have to be

boosted  gas.Gas booster can untilize all the gas from a supply source such as cylinder and boost the gas to whatever  

pressure and flows are required  by the application thus untilizing all the gas volume from the supply source  .

Good quality USUN Model:WS-FM06-A  portable  HFC-227ea/FM200/NOVEC fire extinguisher refilling  machine

 Application : Nitrogen filling stations ,charging high pressure gas cylinders and receivers  .Gas assisted plastic injection

molding Hydraulic accumulator charging ,Components testing ,Automotive hoses and component gas testing ,biogas charging
and pressure tank vessel leakage testing
Good quality USUN Model:WS-FM06-A  portable  HFC-227ea/FM200/NOVEC fire extinguisher refilling  machine
Application :
Nitrogen filling stations ,charging high pressure gas cylinders and receivers  .Gas assisted plastic injection
molding Hydraulic accumulator charging ,Components testing ,Automotive hoses and component gas testing ,biogas charging
and pressure tank vessel leakage testing
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine

Product Description

Product Description
 

Item Model

WS-FM-06-A Automatic refilling machine  Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
Action type Single stage,single air drive

Air drivenpressure

3-10 Bar

Dealing withair source

Compressed and dry air and airregulator on air driven port

Lubrication Non and Non-lubrication for oxygen gas
Theory of operation

The gas booster consist of a

 

large reciprcating air driven

piston directly and coupled by a

connecting rod to small area gas piston.The gas piston operates in a high pressure gas barrel section

.Each gas barrel end contains highpressure inlet and outlet check valves

Suitablegases forpumping

Nitrogen(N2), Helium (He2) ,Breathing air

(N202) ,Carbon dioxideCo2)Argon (Ar) ,Neon( Ne) ,Oxygen(O2) and so on .

Noted:Liquefied gases(  Propane,Co2 ,halons) Can be boosted as a liquid and gas in controlled applications

Net weight  70 kgs 
Dimension  85 L x 60 W X 90 H  CM 

Product  features

1. Realiable ,Easy to Maintain ,compact and robust

2. No heat,flame or spark risk

3. Infinitely variable cycling speed and output

4. Air driven Models do not require electrical connection ,easy to apply automatic controls

5. No limit or adverse affect to contineous stop/start applications

6.Seals system designed for long working life,No airline lubricated required

7.Built-in coupling system (Most models) and suitable for most gases boosting

Main components
Model
: WS-FM-6A  Automatic FM200 Fire extinguisher filling equipment with electronic scale  and Vacuum pump  and air gas booster pump   ,sensors for alarm of weighing  Electrical control box included

Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine1. Machine Composition

WS-FM-6A model FM200 filling machine including air-driven gas filling pump, precision pressure gauge,

pressure reducing valve, high pressure electromagnetic valve, electric control part

and electronic scale, vacuum pump, etc.

2. Filling pump  Machine charaterics

WS-FM-6A filling machine using the compressed air as power source, Through Wellness  air driven gas

booster and filling pump, driving the FM200/NOVEC filling and conveying, when the transmission weight

reaches a certain value, the sensor signal is transferred to the gas electromagnetic valve, the driven air will

stop automaticlly,and pump stops working.

Then Connecting the  nitrogen gas source, open the high-pressure nitrogen gas valve and start the injection

of nitrogen; when precision pressure gauge shows the needed nitrogen pressure then close the nitrogen

valve; filling finished; It has the characteristics of small volume, light weight, simple operation, reliable

performance. Especially suitable for the filling of FM-200/NOVEC in fire fighting industry
3. Main parameters:

Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

Working medium  :   FM200/ NOVEC/Nitrogen

Boost ratio: 5:1

Output pressure: 4  Mpa/5 MPA

Driven air inlet port: fast insert 12 per cent


Nitrogen/FM200 inlet port: ZG3/8 internal thread  ( Thread can be customized base on customer"s

requirements  )

 High pressure gas outlet port: ZG3/8 internal thread  ( Thread can be customized base on

Customer"s requirements )

  Main technical data for  WB06 AIR DRIVEN FM200 PUMP
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
 PA= Air driven pressure   PI=Inlet pressure  Po=Outlet pressure

Those data is theoretical and it is just for reference  .

 Layout drawing of such FM200 refilling machine
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling MachineWorking circuit of such FM200 system
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling MachineReal photos of such FM200 refilling system
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling MachineProduct diagran

Operating Procedure

1.  Add lubricating oil to the FR.L Combination, the South with 10# or 20# mechanical oil, the northern winter with antifreeze mecha
 
nical oil or low condensate hydraulic oil.

 2.Close the driving air ball valve, connected to the compressed air source and let driving air pressure not more than 0.8MPa (8 bar).

3,  Place the good empty cylinder, close the FM200
VEC switch, close the high pressure nitrogen switch, open the vacuum pump switch, start the vacuum pump to vacuum.
 
Note: The vacuum for the 150 liter bottle takes about 6 minutes,

Filling time is about 6-8 kg per minute
Packaging &shipping
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling MachineShipping
By sea Cheapest but longest option 18~30 days by sea delivery for mass shipment
By air More expensive than sea delivery, But cheaper than express 5~7 days by air to airport.
By express door to door service,the fastest and most expensive one, 3~5 day for DHL /Fedex /UPS/TNT express


Company Information
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
Dongguan Usun Fluid Equipment Co Ltd Ltd, its a machinery factory, was founded in DongGuan,GuangDong

Province in 2007 which  Specializing in making Hydro-Pneumatic product such as Air driven gas booster

,hydro-pneumatic pump ,air hydro pump ,High pressure stainless needle valve ,high pressure complete

gas/hydraulic booster system for many hydro-pneumatic machinery and automatical

Having worked in numerous industries for years, our various experiences benefit us by knowing how to

provide customers with the most efficient solutions.

Having worked in numerous industries for years, our various experiences benefit us by knowing how to

provide customers with the most efficient solutions.We have also already exported for many countries

for our High pressure pump and high pressure system to USA ,North America ,Europe ,Middle east
and south America and so on  .
Business partners
Usun Model: Ws-FM-06-a Automatic Hfc- 227ea FM200 Fire Suppression Cylinder Gas Refilling Machine
FAQ

How do I select a correct model


1. Free to inform us that your Inlet gas Pressure range

2.  Kindly advise your needed output pressure for connecting machine

3. Should be kindly informed the Gas flow at the rated pressure for calculating the suitable pressure

ratio base on customer"s requirement 

4.Feel kindly advise us the avaible air driven pressure

5.We suggest a suitable model base on above technical data



What is the warranty for product

1.We have 1 Year Warranty for product and can send some easy wear out repairing parts for fixing

the pump  such as important seal kits 
2.Customer should cover the to-and fro shipping cost for repairing if goods is out of warranty peroid
 

Send your message to this supplier