Customization: | Available |
---|---|
Flow Rate: | Constant Pump |
Type: | Air Driven Pump |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Main technical parameter | |||||||
Model | Pressure ratio | Minimum inlet pressure PI(Bar) | Maximum Outlet pressure PO(Bar) | Outlet pressure formula PO | Inlet port size | Outlet porst size | Maximum Flow rate L/min= 7 Bar |
AB02 | 2:01 | 1 | 16 | 2PA | PT3/8'' | PT3/8'' | 513@PI=7 |
AB03 | 3:01 | 1 | 24 | 3PA | PT3/8'' | PT3/8'' | 420@PI=7 |
4AB02 | 2:01 | 1 | 16 | 2PA | PT1/2'' | PT1/2'' | 1450@PI=7 |
AB04 | 4:01 | 1.7 | 32 | 4PA | PT3/8'' | PT3/8'' | 382@PI=7 |
AB05T | 5:01 | 1.7 | 41.5 | 5PA+PI | PT1/2' | PT1/2'' | 710@pi=7 |
AB07 | 7:01 | 3.4 | 56 | 7PA | PT3/8'' | PT3/8'' | 274@PI=7 |
AB08T | 8:01 | 3.4 | 67.4 | 8PA+ PI | PT3/8'' | PT3/8'' | 482@pi=7 |
AB10 | 10:01 | 3.4 | 80 | 10PA | PT3/8'' | PT3/8' | 225@PI=7 |
AB15 | 15:01 | 8.1 | 120 | 15PA | PT3/8'' | PT3/8' | 185@PI=7 |
PA= Air driven pressure PI=Inlet pressure Po=Outlet pressure ,the flow rate is theoretical data and should have difference between real data | |||||||
AIR AMPLIFIER PRODUCT COMPARISON TABLE
To select the right amplifier for your application you will need to
know the following parameters:
The available air pressure & volume
The desired pressure and flow rate
If you are unsure of these parameters but know a competitor brand's model number,
use the air amplifier product comparison table below to help you choose the
right USUNp air amplifier.
USUN | Haskel | Maximator | Maxpro | HII |
AB04 | SPLV3 | DLA5-1 | ||
AB07 | AA-8 | |||
AB10 | ||||
AB15 | AA-15 | DLA15-1 | ||
AB05T | AAD-5 | GPLV5 | DLA5 | 5A-DS-5 |