Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank

Product Details
Customization: Available
Warranty: 1 Year
Max.Head: None
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
73901.09 USD
Management System Certification
ISO 9001
  • Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank
  • Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank
  • Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank
  • Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank
Find Similar Products

Basic Info.

Model NO.
Model: GT100
Pressure Medium
Water
Type
Handheld
Position of Pump Shaft
Horizontal
Certification
CE
Material
Stainless Steel
Driven Power
Compressed Air of 3-8 Bar
Power
Pneumatic Power
Application
for Charging Cylinder ,Pressure Test
Model
Gh
Driven Cylinder Diameter
250mm
Product Name
Pneumatic Driven Chemical Injection Pump
Transport Package
Foam Inside, Carton Box /Wooden Box Outside
Specification
CE/ ISO9001
Trademark
USUN
Origin
Made in Dong Guan / China
HS Code
8412310090
Production Capacity
100 PCS Per Week

Product Description

Customized  Usun Model : GT 250 MM driven high flow  double acting  air driven

chemical  injection pressure pump for metering  



Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank


General Information for Air driven liquid pumps

Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank



 

USUN air driven liquid  pumps are ratio devices that utilize low pressure compressed

 

air driving a larger diameter piston (area x pressure) which is linearly connected to a smaller

 

hydraulic piston/plunger. Using this ratio principal, a higher hydraulic pressure can be generated.

 

Usun Pump model numbers reflect the pumps nominal pressure ratio, while the technical data 

 

indicates exact ratios.  The outlet stall pressure is easy to set by adjusting the air drive pressure

 

through a simple air pressure regulator. 

 

By multiplying the pressure ratio by the available shop

 

air pressure, the nominal liquid pressure can be calculated.

 

Exmple ( Pump Model: GH40 liquid pump)

 

Air drive piston area ( 250mm Ø)

 

Hydraulic plunger area ( 40 mm Ø)

 

Actual ratio = 40:1


 

1.  AIR DRIVE SECTION

 

The air drive section consists of a light weight piston complete with seals running inside an

 

aluminum barrel. The diameter of the air piston is 80mm. When compressed air is supplied to

 

the pump the air pushes the air piston down on a compression stroke

 

( forces fluid out of the liquid end).

 

 Under the control of pilot pins (poppet valve) triggered at each end of the stroke

 

2. HYDRAULIC SECTION (Wetted End)

 

The hydraulic section of an air driven liquid pump consists of 4 main pieces, the hydraulic body,

 

the piston/plunger, the check valves and the main high pressure seal. The hydraulic

 

piston/plunger is  directly linked to the air piston and it is housed inside the hydraulic body and

 

its movement up and down creates the liquid flow into and out of the pump through the check

 

valves. The check valves are spring loaded and on the suction stroke the inlet check valve

 

 opens to the maximum allowing fluid into the hydraulic body and on the compression stroke the

 

inlet check valve closes and the discharge check valve opens forcing the pumped fluid into the

 

process. The main high pressure seal is located within the hydraulic body and the piston/plunger seals

 

against this during operation. There are different materials and designs of high pressure seals

 

depending on the fluid being pumped and the maximum pressures of the pump, however the

 

standard seals are suitable for both water and hydraulic fluid use.

 

USUN air driven liquid pumps are self-priming, However, high ratio pumps are more difficult to

 

Prime and may require bleeding. In general, it is not recommended to use an air- line lubricator.

 

USUN  air driven liquid pumps cycle automatically  as the outlet pressure increases the

 

resistance  also increases and the cycle rate decreases until the pump stops automatically

 

when the output  pressure forces are equal. This is referred to as the stall condition.

 

The pump will restart with a slight drop in the outlet pressure or an increase in the air drive

 

pressure. Pump performance can be affected by a number of conditions, such as freezing of the

 

exhaust muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air-line

 

sizes and dirty filers. When operating the pumps on a continuous basis, we recommend you use

 

a maximum cycle rate of 50~60 cycles per minute.

 

This will both increase service intervals and assist in preventing ice forming

 

at the exhaust. An air supply dryer will also assist in reducing icing up.

 

To obtain best overall performance, it is recommended not to reduce the indicated port sizes

 

and consult We for flow conditions not shown in charts.

Typical applications for high pressure pneumatic water testing pump 

Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank


Key features

One model available in 8 ratios

Compatibility with a variety of liquids

Safe pneumatic operation

Aluminum bodies and wetted materials of carbon steel or stainless steel

Rugged,compact,reliable and easy maintenance proven design

High quality seals, long service life available

No need for air line lubrication

Wide application with large range of pressure ratio

Main technical data 

Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank





Typical technical data for air  driven chemical injection pump  
 

 GT serial High flow pneumatic chemical injection pump  
                          
Air driven pressure at 7 bar                                                                                   At 0 bar pressure  ,air consumption is around  1.6 M3 per min  
Model Piston/Rod diameter ø(mm) Displacement per stroke(mL) Liquid  IN Liquid OUT Max presusre Bar at driven pressure 8.3Bar Liquid outlet (Bar)     1Bar=0.1Mpa=1.019Kg/cm²
0 20 40 70 100 150 200 300 400 500 600 700 900 1200 1700 2350
Flow rate   L/Min 
GT10 80 1407.43 PT3/4" PT3/4" 83 168.89 140.74 126.67 112.59 98.52 84.45 0                  
GT25 50 549.78 PT3/4" PT3/4" 207 65.97 54.98 49.48 43.98 38.48 32.99 27.49 21.99 16.49              
GT40 40 351.86 PT3/4" PT3/4" 332 42.22 38.7 35.19 33.43 29.91 26.39 21.11 17.59 14.07 12.32 10.56 0        
GT69 30 197.92 PT3/4" NPT1/2" 572 23.75 22.76 21.77 19.79 17.81 15.83 13.85 11.88 9.9 7.92 6.93 5.94 1.98      
GT100 25 137.44 NPT1/2" NPT1/2" 830 16.49 15.81 15.12 14.43 13.74 12.37 11 9.62 8.25 6.87 5.5 4.81 4.12 1.37    
GT156 20 87.96 NPT1/2" *HF6 1295 10.56 10.12 9.68 9.24 8.8 7.92 7.04 6.16 5.28 4.4 3.52 3.08 2.64 2.2 1.76  
GT190 18 71.25 NPT3/8" *HF6 1577 8.55 8.19 8.19 7.84 7.48 7.13 6.41 5.7 4.99 4.28 3.56 3.21 2.85 3.21 1.78  
GT240 16 56.3 NPT3/8" *HF6 2116 6.76 6.47 6.47 6.19 5.91 5.63 5.07 4.5 3.94 3.38 2.82 2.53 2.25 2.14 1.97 1.41


Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using


of such pump ,we suggest that air driven pressure should be not more than 8 Bar 


Typical diagram of such air driven liquid pumps 

Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank

 


Product Applications 

Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank



 

Factory corners 

Usun Model: GT100 Max 80MPa High Pressure Air Driven Water Testing Pump for Big Tank



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier