  • Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
  • Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
  • Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
  • Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
  • Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
Find Similar Products

Basic Info.

Model NO.
AT10-CO2
Max.Head
None
Max.Capacity
<50 L/min
Pressure Medium
Water
Type
Handheld
Position of Pump Shaft
Horizontal
Certification
CE
Material
Stainless Steel
Driven Power
Compressed Air of 3-8 Bar
Power
Pneumatic Power
Application
for Charging Cylinder ,Pressure Test
Model
At10-CO2
Driven Cylinder Diameter
160mm
Net Weight
20 Kgs
Transport Package
Foam Inside, Carton Box /Wooden Box Outside
Specification
CE/ ISO9001
Trademark
USUN
Origin
Made in Dong Guan / China
HS Code
84123100
Production Capacity
100 PCS Per Week

Product Description

USUN Model:AT10-CO2 20-80 Bar Output Stainless steel piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher


Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher

General Information for Air driven liquid pumps

Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher



 

USUN air driven liquid  pumps are ratio devices that utilize low pressure compressed air driving a larger diameter piston (area x pressure) which is linearly connected to a smallerhydraulic piston/plunger. 

Using this ratio principal, a higher hydraulic pressure can be generated.

Usun Pump model numbers reflect the pumps nominal pressure ratio, while the technical data indicates exact ratios.  

The outlet stall pressure is easy to set by adjusting the air drive pressure through a simple air pressure regulator. 

By multiplying the pressure ratio by the available shop air pressure, the nominal liquid pressure can be calculated.

 

1.  AIR DRIVE SECTION

The air drive section consists of a light weight piston complete with seals running inside an aluminum barrel. 

The diameter of the air piston is 80mm. When compressed air is supplied to the pump the air pushes 

the air piston down on a compression stroke( forces fluid out of the liquid end).

 Under the control of pilot pins (poppet valve) triggered at each end of the stroke

2. HYDRAULIC SECTION (Wetted End)

The hydraulic section of an air driven liquid pump consists of 4 main pieces, the hydraulic body,the piston/plunger, 

the check valves and the main high pressure seal. 

The hydraulic piston/plunger is  directly linked to the air piston and it is housed inside the hydraulic body and its 

movement up and down creates the liquid flow into and out of the pump through the check valves. 

The check valves are spring loaded and on the suction stroke the inlet check valve opens to the maximum allowing 

fluid into the hydraulic body and on the compression stroke the inlet check valve closes and the discharge check valve 

opens forcing the pumped fluid into the process.

The main high pressure seal is located within the hydraulic body and the piston/plunger seals against this during operation. There are different materials and designs of high pressure seals depending on the fluid being pumped and the 

maximum pressures of the pump, however the standard seals are suitable for both water and hydraulic fluid use.

USUN air driven liquid pumps are self-priming, However, high ratio pumps are more difficult to

Prime and may require bleeding. In general, it is not recommended to use an air- line lubricator.

USUN  air driven liquid pumps cycle automatically  as the outlet pressure increases the resistance  also increases and 

the cycle rate decreases until the pump stops automatically when the output  pressure forces are equal. 

This is referred to as the stall condition.

The pump will restart with a slight drop in the outlet pressure or an increase in the air drivepressure. 

Pump performance can be affected by a number of conditions, such as freezing of the exhaust muffler or pilot valves (which is caused by moisture in air lines), inadequate inlet air-line sizes and dirty filers. When operating the pumps on a continuous basis, 

we recommend you use a maximum cycle rate of 50~60 cycles per minute.

This will both increase service intervals and assist in preventing ice forming at the exhaust. An air supply dryer will also assist in reducing icing up.

To obtain best overall performance, it is recommended not to reduce the indicated port sizes and consult We for flow conditions not shown in charts.

Typical applications for  pneumatic driven water testing pump  

Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher

Key features

One model available in 8 ratios

Compatibility with a variety of liquids

Safe pneumatic operation

Aluminum bodies and wetted materials of carbon steel or stainless steel

Rugged,compact,reliable and easy maintenance proven design

High quality seals, long service life available

No need for air line lubrication

Wide application with large range of pressure ratio

Main technical data 
Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using
of such pump ,we suggest that air driven pressure should be not more than 8 Bar 


Product Dimension Drawing
Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire ExtinguisherReal photos of the product
Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher
Typical diagram of such air driven liquified CO2 pumps 

Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher

Product Applications 

Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher

Factory corners 

Usun Model: At10-CO2 20-80 Bar Output Stainless Steel Piping Double Acting Faster Refilling Air Driven Liquid CO2 Transfer Pump for Fire Extinguisher

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Send Inquiry
Chat Now