Customization: | Available |
---|---|
Max Diameter of Workpiece: | <500mm |
Mass Scope of Workpiece: | <900kg |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SPECIFICATIONS FOR MANUAL CONTROL PNEUMATIC DRIVEN HYDRAULIC TUBE BURST TEST EQUIPMENT | |||
Air hydraulic pump |
Pump Model | UG400 or AT400 | Maximum 400 Mpa/58000PSI |
pressure ratio | 400:1 | 4000 bar base on 10 bar air pressure | |
Drive power | Compressed air | 3-10 Bar | |
Main performance parameters |
Maximum flow rate | L/Min | 0.48 |
Testing medium | Oil or water or hydraulic liquid | VG46 or VG32 hydraulic oil | |
Max. bursting pressure | Bar | 4000 Bar | |
Control system |
working station | 1 Station or multi | |
IPC | Computerise control | ||
Power supply | KW | 5.5 or 7.5 |
2.System technical parameters and composition
Model:BPT400-CC
BPT- Burst pressure test bench
400-------400:1 ratio air hydraulic pump ( AT400 or AH400 or UG400 )
CC------- Computer control or MC manual control mode
Drive source: clean compressed air
Driven by compressed air pressure: 3-8bar (recommended driving pressure of ≤8bar)
The maximum air consumption: 460LN/min (6 kg)
The maximum output pressure: 0-3200 bar.
3. Working principle
Typical technical data for air driven liquid pump
AT Serial Air liquid pump | |||||||||||||||||||||
Technical data Base on air driven at 7Bar , air consumption is around 0.9M3 per min | |||||||||||||||||||||
Base on air driven pressure at 7Bar | |||||||||||||||||||||
Model | Piston/Rod diameter ø(mm) | Displacement per stroke (mL) | Liquid IN | Liquid OUT | Maximum outlet pressyre Bar@at 8.3Bar | Liquid Outlet pressure (Bar) 1Bar=0.1Mpa=1.019Kg/cm² | |||||||||||||||
0 | 20 | 40 | 70 | 100 | 150 | 200 | 300 | 400 | 500 | 600 | 700 | 900 | 1200 | 1700 | 2350 | ||||||
Flow rate L/min (L/min) | |||||||||||||||||||||
AT10 | 50 | 294.52 | NPT3/4'' | NPT3/4" | 83 | 35.34 | 26.51 | 20.62 | 17.67 | 11.78 | |||||||||||
AT16 | 40 | 188.5 | NPT3/4" | NPT3/4" | 132.8 | 22.62 | 16.97 | 13.2 | 11.31 | 7.54 | |||||||||||
AT20 | 35 | 144.32 | NPT3/4" | NPT3/4" | 166 | 17.32 | 14.43 | 12.99 | 11.55 | 10.1 | 0 | ||||||||||
AT28 | 30 | 106.03 | NPT1/2" | NPT1/2" | 232.4 | 12.72 | 10.6 | 9.54 | 8.48 | 7.42 | 6.36 | 0 | |||||||||
AT40 | 25 | 73.63 | NPT1/2" | NPT1/2" | 332 | 8.84 | 7.36 | 6.63 | 5.89 | 5.15 | 4.42 | 3.68 | 0 | ||||||||
AT64 | 20 | 47.12 | NPT3/8" | NPT3/8" | 498 | 5.65 | 4.71 | 4.24 | 3.77 | 3.3 | 2.83 | 2.36 | 1.88 | 1.41 | |||||||
AT80 | 18 | 38.17 | NPT3/8" | NPT3/8" | 664 | 4.58 | 3.82 | 3.44 | 3.05 | 2.67 | 2.29 | 1.91 | 1.53 | 1.34 | 1.15 | ||||||
AT100 | 16 | 30.16 | NPT3/8" | NPT3/8" | 830 | 3.62 | 3.32 | 3.02 | 2.87 | 2.56 | 2.26 | 1.81 | 1.51 | 1.21 | 1.06 | 0.9 | 0 | ||||
AT130 | 14 | 23.09 | NPT3/8" | NPT3/8" | 1079 | 2.77 | 2.66 | 2.54 | 2.31 | 2.08 | 1.85 | 1.62 | 1.39 | 1.15 | 0.92 | 0.81 | 0.69 | 0.23 | |||
AT170 | 12 | 12.44 | NPT3/8" | NPT3/8" | 1411 | 1.49 | 1.43 | 1.37 | 1.31 | 1.24 | 1.12 | 1 | 0.87 | 0.75 | 0.62 | 0.5 | 0.44 | 0.37 | 0.12 | ||
AT240 | 10 | 8.64 | NPT3/8" | *HF4 | 1992 | 1.04 | 0.99 | 0.95 | 0.91 | 0.86 | 0.78 | 0.69 | 0.6 | 0.52 | 0.43 | 0.35 | 0.3 | 0.26 | 0.22 | 0.17 | |
AT300 | 9 | 7.32 | NPT1/4" | *HF4 | 2490 | 0.88 | 0.84 | 0.84 | 0.81 | 0.77 | 0.73 | 0.66 | 0.59 | 0.51 | 0.44 | 0.37 | 0.33 | 0.29 | 0.33 | 0.18 |
Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using
of such pump ,we suggest that air driven pressure should be not more than 8 Bar .
Product Applications
Factory corners