• Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine
  • Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine
  • Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine
  • Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine
  • Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine

Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine

After-sales Service: 1 Year
Warranty: 1 Year
Max.Head: None
Max.Capacity: <50 L/min
Pressure Medium: Gas
Type: Desktop
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Model: Ws-FM-5A
Position of Pump Shaft
Horizontal
Material
Stainless Steel
Driving Air Pressure
Compressed Air of 3-8 Bar
Pump Type
Piston Pump
Application
Can Be Used for Hose Pressure Testing
Air Driven Port
G1/2′′
Lubrication
Yes
Name
Manual Control Air Safety Relief Valve Test Bench
Transport Package
Carton Box Packing
Specification
1100x850x1700MM
Trademark
USUN
Origin
China
HS Code
8412310090
Production Capacity
2000 PCS Per Year

Product Description

Model : WS-FM-5A   FM200/CO2 fire extingusiher refilling machine   Electronic scale  and Vacuum pump  and  5:1

ratio  air gas booster pump  or 6:1 air gasbooster  pump   ,sensors for alarm of weighing  Electrical control box

included  for automatical controlling .

Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine

1. Machine Composition

 

WS-FM-5A model FM200 filling machine including air-driven gas filling pump, precision pressure gauge,

 

pressure reducing valve, high pressure electromagnetic valve, electric control part

 

and electronic scale, vacuum pump, etc.

 

2. Filling pump  Machine charaterics 

 

US-FM-5A filling machine using the compressed air as power source, Through Wellness  air driven gas

 

booster and filling pump, driving the FM200 filling and conveying, when the transmission weight

 

reaches a certain value, the sensor signal is transferred to the gas electromagnetic valve, the driven air will

 

stop automaticlly,and pump stops working. 

 

Then Connecting the  nitrogen gas source, open the high-pressure nitrogen gas valve and start the injection

 

of nitrogen; when precision pressure gauge shows the needed nitrogen pressure then close the nitrogen

 

valve; filling finished; It has the characteristics of small volume, light weight, simple operation, reliable

 

performance. Especially suitable for the filling of FM-200 in fire fighting industry


3. Main parameters:
Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine
Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine


The driving source: compressed air (by air compressor, need 3-8 bar air pressure)

Working medium  :   FM200/ Nitrogen

Boost ratio: 5:1 or 6:1  

Output pressure: 4  Mpa/5 MPA 

Driven air inlet port: fast insert 12 per cent 

Nitrogen/FM200 inlet port: ZG3/8 internal thread  ( Thread can be customized base on customer"s requirements  ) 

High pressure gas outlet port: ZG3/8 internal thread  ( Thread can be customized base on Customer"s requirements )

Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine

4. Operating Procedure

1.  Add lubricating oil to the FR.L Combination, the South with 10# or 20# mechanical oil, the northern winter with antifreeze mechanical oil or low condensate hydraulic oil.

2,  Close the driving air ball valve, connected to the compressed air source and let driving air pressure not more than 0.8MPa (8 bar).

3,  Place the good empty cylinder, close the FM200 switch, close the high pressure nitrogen switch, open the vacuum pump switch, start the vacuum pump to vacuum.

4,  When vacuum pumping is completed, close the vacuum pump pressure switch, close the unloading valve, open high pressure needle valve and low pressure air driven source ball valve, the filling pump starts, observing the change of the weight of the electronic scale; (when the set weight is reached, pump will stop working automatically), then close the switch of FM200

5,  After the completion of the FM200  filling, open nitrogen valve, observe valve before the pressure gauge (pressure standard table), through
pressure reducing valve to the desired pressure (pressure reducing valve after the precision pressure display) by adding nitrogen to the filling

bottle;

6,  After the completion of the operation, close the high-pressure valve, manual ball valve and nitrogen valve;


Factory corners 

Usun Model: Ws-FM-5A FM200 or CO2 Automatic Fire Extinguisher Filling Machine

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now