Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump

Product Details
Customization: Available
Max.Head: None
Max.Capacity: <50 L/min
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
73901.09 USD
Management System Certification
ISO 9001
  • Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump
  • Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump
  • Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump
  • Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump
  • Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump
  • Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump
Find Similar Products

Basic Info.

Model NO.
Model: AT
Pressure Medium
Water
Type
Handheld
Position of Pump Shaft
Horizontal
Certification
CE
Material
Stainless Steel
Driven Power
Compressed Air of 3-8 Bar
Power
Pneumatic Power
Application
for Charging Cylinder ,Pressure Test
Warranty
1 Year
Model
at
Driven Cylinder Diameter
160mm
Net Weight
20 Kgs
Transport Package
Foam Inside, Carton Box /Wooden Box Outside
Specification
CE/ ISO9001
Trademark
USUN
Origin
Made in Dong Guan / China
HS Code
8412310090
Production Capacity
100 PCS Per Week

Product Description

Popular  Usun Model :AT  type  hose or pipes  or valve  air driven liquid

pressure   testing pump  

Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump




General Information for Air driven liquid pumps

Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump



 

USUN air driven liquid  pumps are ratio devices that utilize low pressure compressed

 

air driving a larger diameter piston (area x pressure) which is linearly connected to a smaller

 

hydraulic piston/plunger. Using this ratio principal, a higher hydraulic pressure can be generated.

 

Usun Pump model numbers reflect the pumps nominal pressure ratio, while the technical data 

 

indicates exact ratios.  The outlet stall pressure is easy to set by adjusting the air drive pressure

 

through a simple air pressure regulator. 

 

By multiplying the pressure ratio by the available shop

 

air pressure, the nominal liquid pressure can be calculated.

 

Exmple ( Pump Model: AT644 liquid pump)

 

Air drive piston area ( 160mm Ø)

 

Hydraulic plunger area ( 20 mm Ø)

 

Actual ratio = 64:1


 

1.  AIR DRIVE SECTION

 

The air drive section consists of a light weight piston complete with seals running inside an

 

aluminum barrel. The diameter of the air piston is 80mm. When compressed air is supplied to

 

the pump the air pushes the air piston down on a compression stroke

 

( forces fluid out of the liquid end).

 

 Under the control of pilot pins (poppet valve) triggered at each end of the stroke

 

2. HYDRAULIC SECTION (Wetted End)

 

The hydraulic section of an air driven liquid pump consists of 4 main pieces, the hydraulic body,

 

the piston/plunger, the check valves and the main high pressure seal. The hydraulic

 

piston/plunger is  directly linked to the air piston and it is housed inside the hydraulic body and

 

its movement up and down creates the liquid flow into and out of the pump through the check

 

valves. The check valves are spring loaded and on the suction stroke the inlet check valve

 

 opens to the maximum allowing fluid into the hydraulic body and on the compression stroke the

 

inlet check valve closes and the discharge check valve opens forcing the pumped fluid into the

 

process. The main high pressure seal is located within the hydraulic body and the piston/plunger seals

 

against this during operation. There are different materials and designs of high pressure seals



Typical applications for  pneumatic driven water testing pump  

Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump


Key features

One model available in 8 ratios

Compatibility with a variety of liquids

Safe pneumatic operation

Aluminum bodies and wetted materials of carbon steel or stainless steel

Rugged,compact,reliable and easy maintenance proven design

High quality seals, long service life available

No need for air line lubrication

Wide application with large range of pressure ratio

Main technical data 
Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump





Typical technical data for pneumatic driven water pump 
 

AT Serial Air liquid pump 
Technical data                                             Base on air driven at 7Bar , air consumption is around  0.9M3 per min 
Base on air driven pressure at 7Bar
Model Piston/Rod diameter ø(mm) Displacement per stroke (mL) Liquid IN Liquid OUT Maximum outlet pressyre Bar@at 8.3Bar Liquid Outlet pressure (Bar)     1Bar=0.1Mpa=1.019Kg/cm²
0 20 40 70 100 150 200 300 400 500 600 700 900 1200 1700 2350
Flow rate   L/min  (L/min)
AT10 50 294.52 NPT3/4'' NPT3/4" 83 35.34 26.51 20.62 17.67 11.78                      
AT16 40 188.5 NPT3/4" NPT3/4" 132.8 22.62 16.97 13.2 11.31 7.54                      
AT20 35 144.32 NPT3/4" NPT3/4" 166 17.32 14.43 12.99 11.55 10.1 0                    
AT28 30 106.03 NPT1/2" NPT1/2" 232.4 12.72 10.6 9.54 8.48 7.42 6.36 0                  
AT40 25 73.63 NPT1/2" NPT1/2" 332 8.84 7.36 6.63 5.89 5.15 4.42 3.68 0                
AT64 20 47.12 NPT3/8" NPT3/8" 498 5.65 4.71 4.24 3.77 3.3 2.83 2.36 1.88 1.41              
AT80 18 38.17 NPT3/8" NPT3/8" 664 4.58 3.82 3.44 3.05 2.67 2.29 1.91 1.53 1.34 1.15            
AT100 16 30.16 NPT3/8" NPT3/8" 830 3.62 3.32 3.02 2.87 2.56 2.26 1.81 1.51 1.21 1.06 0.9 0        
AT130 14 23.09 NPT3/8" NPT3/8" 1079 2.77 2.66 2.54 2.31 2.08 1.85 1.62 1.39 1.15 0.92 0.81 0.69 0.23      
AT170 12 12.44 NPT3/8" NPT3/8" 1411 1.49 1.43 1.37 1.31 1.24 1.12 1 0.87 0.75 0.62 0.5 0.44 0.37 0.12    
AT240 10 8.64 NPT3/8" *HF4 1992 1.04 0.99 0.95 0.91 0.86 0.78 0.69 0.6 0.52 0.43 0.35 0.3 0.26 0.22 0.17  
AT300 9 7.32 NPT1/4" *HF4 2490 0.88 0.84 0.84 0.81 0.77 0.73 0.66 0.59 0.51 0.44 0.37 0.33 0.29 0.33 0.18  
AT400 8 5.53 NPT1/4" *HF4 3320 0.66 0.64 0.64 0.61 0.58 0.55 0.5 0.44 0.39 0.33 0.28 0.25 0.22 0.21 0.19 0.14


Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using


of such pump ,we suggest that air driven pressure should be not more than 8 Bar 


Typical diagram of such air driven liquid pumps 

Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump

 


Product Applications 

Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump


Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump


Usun Model: at Hose or Pipes or Valve Air Driven Liquid Pressure Testing Pump



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier