  • High Pressure Output: Delivers 300-500 Bar pressure for helium balloon refilling applications.
  • Air Driven Operation: No electrical connection required; uses compressed air (3-8 Bar) for safe operation.
  • Explosion Proof Design: No heat, flame, or spark risk, suitable for hazardous environments.
  • Stainless Steel Construction: Durable stainless steel material ensures long service life and corrosion resistance.
  • Automatic Stall Control: Pump stops automatically when outlet pressure forces equalize, preventing over-pressurization.
  • Low Cycle Rate: 120mm stroke reduces cycle rates to minimize freeze-up conditions and extend service intervals.
  • CE Certified: Product meets CE safety and quality standards for international markets.
  • Compact and Robust: Lightweight handheld design with reliable, easy-to-maintain structure.

Product Images of Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling

Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling pictures & photos
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling pictures & photos
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling pictures & photos
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling pictures & photos
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling pictures & photos
Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
  • Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
    Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
  • Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
    Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
  • Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
    Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
  • Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
    Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
  • Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling
    Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling

Find Similar Products

Product Description

 USUN Model :GBD60  160MM driven 300-500 Bar Double action high pressure


 pneumatic helium booster pump for balloon refilling  



Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling


 

Usun air driven gas booster  pumps are ratio devices that utilize low pressure compressed

 

air driving a larger diameter piston (area x pressure) which is linearly connected to a smaller

 

hydraulic piston/plunger. Using this ratio principal, a higher hydraulic pressure can be generated.

 

Usun Pump model numbers reflect the pumps nominal pressure ratio, while the technical data 

 

indicates exact ratios.  The outlet stall pressure is easy to set by adjusting the air drive pressure

 

through a simple air pressure regulator. By multiplying the pressure ratio by the available shop

 

air pressure, the nominal gas  pressure can be calculated.

 

Example ( Pump Model: GBD40 Gas booster pump)

 

Air drive piston area ( 160mm Ø)

 

Hydraulic plunger area ( 25mm Ø)

 

Actual ratio = 40:1

 

 1.  AIR DRIVE SECTION

 

The air drive section consists of a light weight piston complete with seals running inside an

 

aluminum barrel. The diameter of the air piston is 160mm. When compressed air is supplied to

 

the pump the air pushes the air piston down on a compression stroke

 

(forces as out of the gas end).

 

 Under the control of pilot pins (poppet valve) triggered at each end of the stroke

 

2. GAS  DRIVEN SECTION

The gas section of a USUN air driven gas booster consisit of 4 main pieces  

 

,the gas barrel  ,the piston the check valves  and the main high pressure seals  .

 

The gaspiston is directly linked to the air piston and it is housedinside the gas barrel 

 

and its movements up and down creates the gas flow into and out of the booster through

 

 the check valves . The check valves are psring loaded and on the suction stroke .the inlet check valve

 

opens to the maximum allowing gas into the gas barrel and on the compression stroke

 

the inlet check valve closes the discharge check valve opens forcing the pumped gas

 

 into the process  .The main high pressure seals is located on the gas piston and they seal agaist


 the gas barrel during operation . and the maximum pressures of the pump ,however the

 

standard PTFE seals are suitable for both the vast majority of gases encountered .

 

Other materials of construction  can be supplied to meet more aggresive services  

 

.The standard  serials of booster are not suitable for underground coal mine applications  .

 

USUN DO Manufacture models of  air driven gas boosters  that are not suitable for underground

coal mine applications .


USUN Air driven gas boosters cycle automatically  as the outlet pressure increass the

 

resistance also increases and the cycle rate decreases until the pump stops automatically 

 

when the out put pressure forces are equal .This is refered to as the stall condition  .

 

The pump will restart with a slight drop in the outllet pressure or an increase in the  air driven pressure 


Booster performance can be affected by a number of conditions ,

 

such as freezing of the exhaust muffler   or pilot valves ( Which is caused by moisture in

 

 air lines  ),inadequate  inlet air line sizes and dirty filers .When  operating the boosters 

 

on a contunuous basis  ,we recommend you use a maximum cycle rate of 50-60 cycles per minute .

 

This will both  increase service intervals  and assist in preventing ice forming at the exhaust  .

 

An air supply dryer will also assist in reducing icing up  .

 

USUN Gas boosters have a 120mm stroke thus reducing cycle rates at any given flow 

 

and pressure as compared with most other brands  . This lower repsective cycle rate res

 

ults in a reduction in freeze-up  condition  .

 

To abtain best overall performance  ,do not reduce the indicated port size and consult


USUN for flow conditions not shown in charts   

Model selection for gas booster  

 It is very important to remember that the performance of any air driven device is very dependent 

on the air supply conditions .Restrictions in the air supply can be caused by using a too small air compressor or 

airlines  .The FLOW CHARTS SHOWN in the technical data sheet are based on good conditions  .

 so please do not "design  to the line "  allow for losses and inefficiencies  

The next question is wheather you want the booster to stall when an outlet pressure is reached 

If so ,a simple airline pressure regulator will suffice ,but remember the flow drops off dramatically as the 

booster reaches a stall condition  .

 If you require flow at a particular pressure ,then you need read the flow cahrts carefully and conservatively  

 If you need the pump to stop at a certain pressure ,prior to stall ,then an air pilor switches needs to be installed  .
 

Key features

1. Realiable ,Easy to Maintain ,compact and robust

2. No heat,flame or spark risk

3. Infinitely variable cycling speed and output

4. Air driven Models do not require electrical connection ,easy to apply automatic controls

5. No limit or adverse affect to contineous stop/start applications

6.Seals system designed for long working life,No airline lubricated required

7.Built-in coupling system (Most models) and suitable for most gases boosting 

Main technical data  

Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling

Typical technical data for air driven gas booster pump  

 

Model High pressure piston rod diameter  Pressure ratio Minimum inlet pressure PI(Bar) Maximum inlet pressure PI ( Bar ) Maximum Outlet pressure PO(Bar) Outlet pressure formula PO Inlet port size Outlet porst size Maximum Flow rate L/min= 7 Bar
GBD07 63 7:1 3.4 56 56 7PA+PI NPT3/8'' NPT3/8'' 392@PI=7
GBD10 50 10:1 6.5 80 80 10PA+PI NPT3/8'' NPT3/8'' 352@PI=7
GBD15 40 15:1 8.1 120 120 15PA+PI NPT3/8'' NPT3/8'' 289@PI=10
GBD25 32 25:1 15 200 207.5 25PA+ PI NPT1/4'' NPT1/4'' 186@PI=20
GBD30 28 32:1 18 240 240 32PA+PI NPT1/4'' NPT1/4'' 165@PI-20
GBD40 25 40:1 25 320 332 40PA+PI NPT1/4' NPT1/4'' 273@pi=40
GBD60 20 60:1 32 480 498 60PA+PI NPT1/4'' NPT1/4'' 175@PI=40
GBD100 16 100:1 40 800 830 100PA+ PI NPT1/4'' NPT1/4'' 136@pi=60

 Remark 1) Maxium outlet pressure are at an air driven pressure of 8 bar or 116 PSI ,for long life using

of such pump ,we suggest that air driven pressure should be not more than 8 Bar  .

Typical application of such double action gas booster 

Usun Model: GBD60 300-500 Bar Double Action High Pressure Pneumatic Helium Booster Pump for Balloon Refilling





 

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI192373". Items marked "verified" are certified.

Watch Video
Watch Video
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.
Dong Guan Usun Fluid Control Equipment Co., Ltd.

About Our Factory & Business Background

verified Business Type
Trading Company
Address
Chuangying Industrial Park, Liaobu Town, Dong Guan City, Guangdong Province, Dongguan, Guangdong, China
verified Plant Area
87 square meters
verified Number of Employees
5
verified Registered Capital
500,000 RMB
verified Terms of Payment
T/T, PayPal
verified International Commercial Terms(Incoterms)
CIF, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shenzhen Port

Our Production Capability & Technical Expertise

verified Main Products
Gas Booster, Gas Booster Pump, Air Hydraulic Pump, Gas Booster System, High Pressure Fittings, High Pressure Needle Valves, Pneumatic Test Bench, Air Liquid Pump, Pneumatic Hydraulic Test Bench
verified Test Reports for Raw Materials
Others

Our Industry Experience & Global Business Record

verified Year of Establishment
2015-08-24
Export Year
2013-10-05
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, East Asia(Japan/ South Korea), Australia
verified Number of Foreign Trading Staff
4
verified Overseas Agent/Branch
No

Our Certifications, Standards & Industry Recognition

verified Product Certification
CE

FAQ

What is the maximum pressure output?
The pump delivers a maximum outlet pressure of 300-500 Bar depending on the specific model and air drive pressure.
Does the pump require electricity?
No, it is an air-driven model that operates using compressed air (3-8 Bar) and requires no electrical connection.
What is the lead time for delivery?
The average lead time is within 15 workdays for both peak and off-peak seasons.
Is the pump suitable for underground coal mines?
No, USUN standard gas boosters are not suitable for underground coal mine applications.
How is the pressure regulated?
The outlet stall pressure is easily set by adjusting the air drive pressure through a simple air pressure regulator.
What materials are used for the seals?
Standard PTFE seals are used, which are suitable for most gases, though other materials can be supplied for aggressive services.
What is the recommended cycle rate?
For continuous operation, a maximum cycle rate of 50-60 cycles per minute is recommended to prevent icing.
What are the payment terms?
We accept T/T and PayPal as terms of payment.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now